Mei Lin Plastic Industry Co,.ltd locates at Luqiao zhejiang ,where is a beautiful beach city ,which special in making a hand sprayer and battey sprayer, that is two series. It is as first task to be developed ,It is as soul and spririts to be innovated teachnology, It is our cognate that is client from company established for our target. we are posilively participating in markets and competion ;construction and cooperation of morden agriculture from all over the world.
The workers and peasants, a 16 knapsack sprayer is the most popular rural, has the largest plant protection machinery. Its common fault inspection and troubleshooting: 1. Nebulizer drug barrels leakage. This is a plastic barrel aging or foreign object damage long-term use, resulting in the collapse of the block or crack and seepage. Remedy: ① adhesive patch. The ② plastic welding. The Q9 replace pesticides ellipsoid. 2 the nebulizer drug the barrel upper pump cap at take water. Here to take water, multi-pump cap mouth deformation, causing the II that cylinder cap prop seal blankets off or deformation. The cap port rod ask ask gap is too large, felt not seal syrup and syrup with a pull with the rod up and down. Remedy: Replace the ji Jane cap, hand held sprayer,pump cap prop seal blankets. 3. Sprayer the water of the the drug barrels left side of the lower part of the seat at the leaking. This is a water valve seat cracks or loosening the lock nut. Remedy: (1) to replace the water valve seat. (2) replace the locking nut, washer, and tighten the lock nut. 4 no liquid into the gas chamber. Failure reasons: (1) water filter clogging. ② inlet valve seat sealing balls to fall, the rust dead or stuck. (3) water valve seat sealing ball rust. Remedy: ① cleaning or replacing the filter. (2) retrofitting sealed steel ball. ③ sealed grinding steel balls. Gas chamber into the liquid insufficient. The cause of the malfunction; pump To wear or cracks. ② skin the bowl anti or damage. Between ⑧ the jack Jane and cup ask gap is too large, resulting in lack of liquid medicine pressure. ④ water the valve seat sealing Ball Mifengbuyan a. ⑤ water the seat sealing balls to fall or Mifengbuyan.manual sprayer ;portable power sprayer
The workers and peasants, a 16 knapsack sprayer is the most popular rural, has the largest plant protection machinery. Its common fault inspection and troubleshooting:
回复删除1. Nebulizer drug barrels leakage. This is a plastic barrel aging or foreign object damage long-term use, resulting in the collapse of the block or crack and seepage. Remedy: ① adhesive patch. The ② plastic welding. The Q9 replace pesticides ellipsoid. 2 the nebulizer drug the barrel upper pump cap at take water. Here to take water, multi-pump cap mouth deformation, causing the II that cylinder cap prop seal blankets off or deformation. The cap port rod ask ask gap is too large, felt not seal syrup and syrup with a pull with the rod up and down. Remedy: Replace the ji Jane cap, hand held sprayer,pump cap prop seal blankets. 3. Sprayer the water of the the drug barrels left side of the lower part of the seat at the leaking. This is a water valve seat cracks or loosening the lock nut. Remedy: (1) to replace the water valve seat. (2) replace the locking nut, washer, and tighten the lock nut. 4 no liquid into the gas chamber. Failure reasons: (1) water filter clogging. ② inlet valve seat sealing balls to fall, the rust dead or stuck. (3) water valve seat sealing ball rust. Remedy: ① cleaning or replacing the filter. (2) retrofitting sealed steel ball. ③ sealed grinding steel balls. Gas chamber into the liquid insufficient. The cause of the malfunction; pump To wear or cracks. ② skin the bowl anti or damage. Between ⑧ the jack Jane and cup ask gap is too large, resulting in lack of liquid medicine pressure. ④ water the valve seat sealing Ball Mifengbuyan a. ⑤ water the seat sealing balls to fall or Mifengbuyan.manual sprayer ;portable power sprayer